Overview
| VDX 6740T-1G
|
Form factor
| 1U
|
Switching bandwidth (data rate, full duplex)
| 1.28 Tbps
|
Switch performance
| 960 Mpps
|
Port-to-port latency
| 3 µs
|
Dimensions and weight
| Width: 43.74 cm (17.22 in.) Height: 4.27 cm (1.68 in.) Depth: 53.65 cm (21.12 in.) Weight: 10.82 kg (23.85 lb)
|
10 GbE SFP+ ports
| Up to 16
|
2/4/8/16 Gbps Fibre Channel Flex Ports
| 0
|
1/10 GBASE-T
| 48
|
40 GbE QSFP+ (10 GbE breakout cable)
| 4
|
10 GbE Ports on Demand (PoD)
| N/A
|
10 GbE Capacity on Demand (CoD)
| 16, 32, 48
|
Power supplies
| Two hot-swappable, load-sharing
|
Cooling fans
| N+1 redundant, five hot-swappable fan units
|
Airflow
| Front to back Back to front
|
Connector options
| Out-of-band Ethernet management: RJ45 (fixed) Console management: RJ45 to RS-232 (fixed) Firmware and diagnostic: USB
|
Maximum VLANs
| 4,096 |
Maximum MAC addresses
| 160,000 |
Maximum port profiles (AMPP)
| 1,024 |
Maximum members in a standard LAG
| 64 |
Maximum per-port priority pause level
| 8 |
Maximum switches that a vLAG can span
| 8 |
Maximum members in a vLAG
| 64 |
Maximum ACLs
| 13,000 |
Maximum ARP entries
| 32,000 |
Maximum IPv4 unicast routes
| 12,000 |
Maximum IPv6 unicast routes
| 3,000 |
HA/ISSU
| ISSU fully supported |
Mechanical
|
Enclosure
| Front-to-rear, rear-to-front airflow; 19-inch EIA-compliant; power from non-port side |
Environmental
|
Temperature
| Operating: 0°C to 40°C (32°F to 104°F) Non-operating and storage: -25°C to 70°C (-13°F to 158°F)
|
Humidity
| Operating: 10% to 85% non-condensing Non-operating and storage: 10% to 90% non-condensing
|
Altitude
| Operating: Up to 3,048 meters (10,000 feet) Non-operating and storage: Up to 12 kilometers (39,370 feet)
|
Shock
| Operating: 20 G, 11 ms half-sine Non-operating and storage: Square wave, 44 G, 15 ms
|
Vibration
| Operating: 0.5 G peak, 0.7 G ms random, 5 to 500 Hz Non-operating and storage: 2.0 g sine, 1.4 G rms random, 5 to 500 Hz
|
Airflow
| VDX 6740T port-side-intake: Maximum: 49.3 CFM; Nominal: 26.3 CFM VDX 6740T port-side-exhaust: Maximum: 51.9 CFM; Nominal: 27.3 CFM
|
Heat Dissipation
| 1,672.41 BTU/hr |
Power
|
Power Supplies
| Two internal, redundant, field-replaceable, load-sharing AC power supplies |
Power Inlet
| C13 |
Input Voltage
| 85 to 264 VAC nominal |
Input Line Frequency
| 50 to 60 Hz |
Inrush Current
| Limited to 30 A peak at 240 VAC during cold startup at 25°C ambien |
Maximum Current
| 66 A max at 100 VAC/60 Hz |
Maximum Power Consumption
| VDX 6740T-1G: 276 W (Base SKU)
|